Shown are two deadmen, each
designed for the SWL of 76 kips for a 1.5"
diameter guyline based on sandy submerged soil. Each deadman is made up of two pieces for
easier handling.
When used for double guy
lines, the deadmen are located in the ground side by side
as shown with the winch mounted on top of the right deadman,
looking from the deadmen to the guy derrick.